ELIS T

Flowair


Color:
SIZE:
VERSION:

Payments: Pagamento acto da entrega
Dimensions: Width: 104.5cm; Height: 26.3cm; Depth: 42.8cm
Weight: 20.5 Kg

Short characteristic:

ELiS T air curtain ensures thermal protection of a room. It prevents the inflow of cold air during the winter and the inflow of warm air into the air-conditioned rooms during the summer.

Thanks to an adjustable air outlet it is possible to adapt the air barrier to the conditions in the door opening. 

Units are available in three lengths: 1m, 1,5m i 2m and in three versions: with water heat exchanger, with electric heaters and without heating elements (“ambient”). 

Casing is made of steel (ral 9007) and EPP (expanded polypropylene). Air inlet made of anodized aluminium profiles ensures a modern look.

 


 

Purpose:

Modern shape and small size makes installation of the units both in representative and industrial buildings possible.

Control system:

Basic operation of the air curtains is ensured by built-in connection terminal. Advanced external DRV control system enables communication with BMS and selection of operation mode.

Technology /Innovation /Benefits:

Construction - combination of several materials including EPP, plastic, steel and aluminium allowed for a significant reduction of weight of the unit, as well as a reduction of the noise level.
 

Specifications of ELIS T
Sku
ELIST


Technical data ELiS T 100

ELiS T-W-100 ELiS T-N-100 ELiS T-E-100
Power supply [V/Hz] 230 / 50 230 / 50 3 x400 / 50
Power consumption [kW]  0,38 0,38   7,5
Current consumption [A]  1,7  1,7  11
IP 21 21 21
Insulation class F F F
Connection (Thread) ["] ½” - -
Air flow   2300 2900 2300
Acoustic pressure level  [dB(A)]*  67  69  67
Max. water temp. [oC] 95 - -
Max. water pressure.[MPa] 1,6 - -
Weight of unit [kg] 22,1 20,7 24
Weight of unit filled with water [kg]  22,9 - -

* Acoustic pressure level measured in the room with average sound absorption, capacity 500 m3, at a distance of 2 m from the unit.

Dimensions ELiS T-N-E 100

t

Dimensions ELiS T-W 100

w

Technical data ELiS T 150

ELiS T-W-150 ELiS T-N-150 ELiS T-E-150
Power supply [V/Hz] 230 / 50 230 / 50 3 x400 / 50
Power consumption [kW]  0,4 0,42  11,5
Current consumption [A]  1,8 1,9  16,6
IP 21 21 21
Insulation class F F F
Connection (Thread) ["] ½” - -
Air flow   3900 4000 3900
Acoustic pressure level  [dB(A)]*  67  69  67
Max. water temp. [oC] 95 - -
Max. water pressure.[MPa] 1,6 - -
Weight of unit [kg]  29,5  27 31,5
Weight of unit filled with water [kg]  30,7 - -

* Acoustic pressure level measured in the room with average sound absorption, capacity 500 m3, at distance of 2 m from the unit.

Dimensions ELiS T-N-E 150

150
 

Dimensions ELiS T-W 150

w

Technical data ELiS T 200

ELiS T-W-200 ELiS T-N-200 ELiS T-E-200
Power supply [V/Hz] 230 / 50 230 / 50 3 x400 / 50
Power consumption [kW]  0,44 0,46  15,5 
Current consumption [A] 2,0   2,1  22,4
IP 21 21 21
Insulation class F F F
Connection (Thread) ["] ½” - -
Air flow   5100 5300 5100
Acoustic pressure level  [dB(A)]* 68  70  68
Max. water temp. [oC] 95 - -
Max. water pressure.[MPa] 1,6 - -
Weight of unit [kg] 34,3  31,5  37
Weight of unit filled with water [kg]  35,9 - -

* Acoustic pressure level measured in the room with average sound absorption, capacity 500 m3, at distance of 2 m from the unit.

Dimensions ELiS T-N-E 200

200

Dimensions ELiS T-W 200

w

Capacidades Térmicas ELiS T 100

ELiS T 100
Tp1 V PT Qw Δpw Tp2 PT Qw Δpw Tp2
°C m3/h kW l/h kPa °C kW l/h kPa °C
Tw1 / Tw2 = 90/70 ˚C Tw1 / Tw2 = 80/60 ˚C
0 1900/2100/2300 11,7/12,3/12,9 516/544/571 1,7/1,8/2 18/17,5/17 9,8/10,3/10,8 430/454/476 1,2/1,4/1,5 15/14,5/14
5 10,9/11,5/12 480/507/531 1,5/1,6/1,8 22/21,5/21 9/9,5/9,9 394/415/436 1,1/1,2/1,3 19/18,5/18
10 10,1/10,6/11,1 444/469/492 1,3/1,4/1,5 25,5/25/24,5 8,1/8,6/9 357/377/395 0,9/1/1,1 22,5/22/21,5
15 9,3/9,8/10,2 408/430/451 1,1/1,2/1,3 29/28,5/28 7,3/7,7/8,1 321/338/355 0,7/0,8/0,9 26/25,5/25
20 8,4/8,9/9,3 372/392/411 0,9/1/1,1 33/32,5/32 6,5/6,8/7,1 283/299/314 0,6/0,6/0,7 30/29,5/29
Tw1 / Tw2 =70/50 ˚C Tw1 / Tw2 = 60/40 ˚C
0 1900/2100/2300 7,8/8,3/8,7 342/361/379 0,8/0,9/1 12/11,5/11 5,7/6/6,3 248/262/276 0,5/0,5/0,6 9/8,5/8
5 7/7,4/7,7 305/322/338 0,7/0,8/0,8 16/15,5/15 4,8/5/5,3 207/220/232 0,4/0,4/0,4 12,5/12/11,5
10 6,1/6,5/6,8 267/282/296 0,5/0,6/0,7 19,5/19/18,5 3,7/3,9/4,2 159/172/183 0,2/0,3/0,3 16/15,5/15
15 5,2/5,5/5,8 229/242/254 0,4/0,5/0,5 23/22,5/22 2/2/2 85/87/89 0,1/0,1/0,1 18,5/18/17,5
20 4,3/4,6/4,8 188/199/210 0,3/0,3/0,4 27/26,5/26 1,6/1,6/1,7 70/71/73 0,1/0,1/0,1 22,5/22/22
Tw1 / Tw2 =70/40 ˚C Tw1 / Tw2 = 50/40 ˚C
0 1900/2100/2300 4,7/5,1/5,4 135/148/158 0,2/0,2/0,2 7,5/7/6,5 6,3/6,7/7 549/579/608 2,1/2,3/2,5 10/9,5/9
5 2,8/2,8/2,9 80/82/84 0,1/0,1/0,1 9,5/9/8,5 5,5/5,8/6,1 475/502/527 1,6/1,8/1,9 13,5/13/12,5
10 2,4/2,5/2,6 70/71/73 0,1/0,1/0,1 13,5/13/12,5 4,6/4,9/5,1 401/423/444 1,2/1,3/1,4 17/16,5/16
15 2,1/2,1/2,1 60/61/62 0,1/0,1/0,1 18,5/18/17,5 3,7/3,9/4,1 324/343/360 0,8/0,8/1 21/20,5/20
20 1,7/1,8/1,8 50/51/52 0,1/0,1/0,1 23/22,5/22 2,8/3/3,1 244/259/272 0,5/0,5/0,6 25/24,5/24

Capacidades Térmicas ELiS T 150

ELiS T 150
Tp1 V PT Qw Δpw Tp2 PT Qw Δpw Tp2
°C m3/h kW l/h kPa °C kW l/h kPa °C
Tw1 / Tw2 = 90/70 °C Tw1 / Tw2 = 80/60 °C
0 3100/3500/3900 20,6/21,9/23,2 907/968/1026 5,8/6,5/7,2 19,5/18,5/17,5 17,5/18,7/19,8 769/821/870 4,4/4,9/5,5 17/16/15
5 19,2/20,5/21,7 848/905/959 5,1/5,8/6,4 23/22/21 16,2/17,3/18,3 710/758/802 3,8/4,3/4,7 20,5/19,5/18,5
10 17,9/19,1/20,2 789/842/892 4,5/5/5,6 27/26/25 14,8/15,8/16,7 650/694/735 3,2/3,6/4 24,5/23,5/22,5
15 16,5/17,7/18,7 730/779/824 3,9/4,4/4,8 31/30/29 13,4/14,3/15,2 591/630/667 2,7/3,1/3,4 28/27/26
20 15,2/16,2/17,2 670/715/757 3,3/3,7/4,1 34,5/33,5/32,5 12,1/12,9/13,6 530/566/599 2,2/2,5/2,8 32/31/30
Tw1 / Tw2 =70/50 °C Tw1 / Tw2 = 60/40 °C
0 3100/3500/3900 14,4/15,4/16,3 631/674/714 3,2/3,6/4 14/13/12 11,3/12/12,8 492/525/556 2,1/2,4/2,6 11/10/9
5 13,1/13,9/14,8 572/610/646 2,6/3/3,3 18/17/16 9,9/10,6/11,2 431/460/487 1,7/1,9/2,1 15/14/13
10 11,7/12,5/13,2 511/546/578 2,2/2,4/2,7 22/21/20 8,5/9/9,6 369/394/417 1,3/1,4/1,6 18,5/17,5/16,5
15 10,3/11/11,6 450/481/509 1,7/1,9/2,1 25,5/24,5/23,5 7/7,5/7,9 305/327/346 0,9/1/1,1 22,5/21,5/20,5
20 8,9/9,5/10 389/415/439 1,3/1,5/1,6 29,5/28,5/27,5 5,5/5,9/6,2 239/256/272 0,6/0,7/0,07 26/25/24
Tw1 / Tw2 =70/40 °C Tw1 / Tw2 = 50/40 °C
0 3100/3500/3900 11,31/12,09/12,8 329/352/373 1/1,12/1,25 11/10/9 11,3/12,07/12,79 983/1050/1113 7,45/8,39/9,32 11/10/90
5 9,88/10,56/11,19 288/307/326 0,8/0,9/1 15/14/13 9,92/10,6/11,22 863/922/977 5,88/6,62/7,35 15/14/13
10 8,39/9/9,53 244/262/278 0,6/0,66/0,8 18,5/17,5/16,5 8,53/9,11/9,65 742/793/839 4,47/5/5,59 18,5/17,5/16,5
15 6,82/7,33/7,8 198/213/227 0,4/0,5/0,5 22/21/20 7,13/7,61/8,06 620/662/701 3,23/3,64/4 22/21/20
20 4,93/5,42/5,85 143/158/170 0,2/0,3/0,3 25/24/23 5,7/6,09/6,45 496/530/561 2,16/2,43/2,7 26/25/24

Capacidades Térmicas ELiS T 200

ELiS T 200
Tp1 V PT Qw Δpw Tp2 PT Qw Δpw Tp2
°C m3/h kW l/h kPa °C kW l/h kPa °C
Tw1 / Tw2 = 90/70 °C Tw1 / Tw2 = 80/60 °C
0 3000/4100/5100 23,5/28/31,4 1037/1234/1387 8,5/11,7/14,5 23/20/18 20,2/24/26,9 885/1052/1183 6,5/9/11,1 19/17/15
5 22/26,2/29,4 972/1155/1299 7,5/10,3/12,8 27/24/22 18,6/22,2/24,9 819/974/1095 5,7/7,8/9,6 23,5/21/19,5
10 20,5/24,4/27,4 906/1077/1211 6,6/9,1/11,3 30/27/26 17,1/20,4/22,9 753/895/1005 4,9/6,7/8,2 27/24,5/23
15 19/22,6/25,4 840/998/1122 5,8/7,9/9,8 34/31/29 15,6/18,6/20,8 686/815/916 4,1/5,6/7 30/28/27
20 17,5/20,8/23,4 774/919/1033 5/6,8/8,4 38/35/33 14,1/16,7/18,8 619/735/826 3,4/4,7/5,8 33,5/32/30,5
Tw1 / Tw2 =70/50 °C Tw1 / Tw2 = 60/40 °C
0 3000/4100/5100 16,8/19,9/22,4 733/872/980 4,8/6,6/8,1 16,5/14,5/12,5 13,3/15,8/17,8 581/690/776 3,3/4,5/5,5 13/11,5/10
5 15,2/18,1/20,6 667/792/891 4/5,5/6,8 20/18/16 11,8/14/15,7 513/610/686 2,6/3,6/4,4 16,5/15/14
10 13,7/16,3/18,3 600/713/801 3,3/4,6/5,6 23,5/21,5/20,5 10,2/12,1/13,6 445/529/595 2/2,7/3,4 20/19/18
15 12,2/14,5/16,2 532/632/710 2,7/3,7/4,5 27/25/24 8,6/10,2/11,5 376/447/502 1,5/2/2,5 23,5/22,5/21,5
20 10,6/12,6/14,4 464/551/619 2,1/2,9/3,5 30,5/28,5/27,5 7/8,3/9,4 304/362/408 1/1,4/1,7 26,5/25,5/25
Tw1 / Tw2 =70/40 °C Tw1 / Tw2 = 50/40 °C
0 3000/4100/5100 13,7/16,3/18,3 399/474/533 1,6/2,2/2,8 13,5/11,5/10,5 13/15,5/17,4 1130/1345/1513 11/15,2/18,8 12,5/11/10
5 12,1/14,4/16,2 353/420/472 1,3/1,8/2,2 17/15/14 11,5/13,6/15,3 997/1186/1334 8,8/12/15 16/14,5/14
10 1,5/12,5/14,1 306/365/410 1/1,4/1,7 20/19/18 9,9/11,8/13,3 862/1025/1153 6,8/9,3/11,5 20/18,5/17,5
15 8,9/10,6/11,9 258/308/347 0,8/1/1,3 23,5/22,5/21,5 8,4/9,9/11,2 726/864/971 5/6,8/8,4 23/22/21
20 7,1/8,6/9,7 207/249/281 0,5/0,7/0,9 27/26/25 6,8/8/9 589/700/786 3,4/4,7/5,8 26,5/25,5/24,5

V - fluxo de ar
PT - capacidade de aquecimento
Tp1 - temperatura do ar de entrada
Tp2 - temperatura do ar de saída
Tw1 - temperatura da água de entrada
Tw2 - temperatura da água de saída