Dimensions: Width: 137cm; Height: 118cm; Depth: 76cm
Weight: 65 Kg

SHORT CHARACTERISTIC:

OXeN is a heating and ventilation unit with heat recovery. It ensures mechanical air supply/exhaust ventilation without any additional need for air ducts. It's an easy to mount, energy efficient, ductless ventilation system.

OxeN is a:
• Ductless unit – ensures low investment and operation costs, it is easy to maintain and it is perfect solution for allready existing buildings.
• Independent unit – every unit is equipped with a complete control system, which ensures intuitive and reliable operation of the unit.
• Compact unit - OXeN is ready to use. It does not require any additional installation consoles because it has installation brackets as a standard.

There are following types of units available:
X2-W-1.2-V – unit with additional heater (water supplied), for on-wall installation.
X2-N-1.2-V – unit without additional air heating, for on-wall installation.
X2-W-1.2-H – unit with additional heater (water supplied), for installation under the ceiling.
X2-N-1.2-H – unit without additional air heating, for installation under the ceiling.

 

PURPOSE:

OXeN meets the demand for units which offer fresh air supply to buildings without the need for additional air duct installation. 

CONTROL SYSTEM:

The OXeN unit is equipped with a complete control system. It is controlled by single control panel called T-box with a touch screen.

TECHNOLOGY/INNOVATION/BENEFITS:

- X2-FLOW  –  High efficiency of heat recovery is a result of application of two cross flow heat exchangers. They are made of aluminium and thanks to this are highly resistant to corrosion.

- MULTI-FAN TECHNOLOGY  –  Unit is equipped with 2 sections of diagonal fans, each section is formed by 3 fans which allows for steady distribution of the supply air flow on the entire surface of the heat exchanger, effective heat exchange, quiet operation and energy efficiency.

- CASING MADE OF EPP  –  Casing of the unit is made of extremely durable and light material. Expanded polypropylene (EPP) provide good thermal insulation, high ability of sound absorption and significant reduction of the total weight of the unit. 

Specifications of OXEN c/ Recuperador de calor
Sku
OX

Technical data OXeN:

X2-W-1.2-V X2-N-1.2-V X2-W-1.2-H X2-N-1.2-H
Max. air flow stream inlet/outlet(1) [m3/h] 1200
Air stream range(2) [m] 15
Air flow regulation inlet/outlet [m3/h] stepless, 150–1200
Acoustic pressure level(3) [dB(A)] 49
Power supply [VAC/Hz] 230/50
Max. current consumption [A] 1,9
Max. power consumption [W] 420
Type of casing EPP – expanded polypropylene
Colour(4) grey
Weight of unit [kg] 69,6 67,2 72,6 70,2
Weight of unit filled with water [kg] 70,4 73,4
Place of installation indoors
Max. air contamination [g/m3] 0,3
Oparating temperature [oC] 5–35
Installation position vertically on the wall under the ceiling
IP 42
Filter class EU4
Type of heat recovery exchanger two-step heat recovery in cross heat exchangers
Thermal efficiency dry / wet(5) [%] 68,4 / 78,9
Type of additional heater water heater water heater
Nominal heating capacity(6) [kW] 10 10
Air temperature rise (ΔT)(6) [oC] 25 25
Connection [”] ½ ½
Max. water pressure [MPa] 1,6 1,6
Max. water temperature [oC] 95 95
Control system controller with touch screen
Antifreeze protection of heat recovery exchanger reduction of fan revs
Antifreeze protection of water heat exchanger temperature mesurement of suppied air and water by PT-1000 sensor temperature mesurement of suppied air and water by PT-1000 sensor

(1) Max. air flow during operation with EU4 filter and OxS air inlet
(2) Range of isothermal air stream, at 0,2 m/s velocity limit
(3) Acoustic pressure level at the distance of 5 m from the unit, in the room of medium capability of sound absorption and 500 m3 of cubature
(4) Similar to 9007
(5) According to directive 2009/125/EC measured with balanced mass flow, an indoor-outdoor air temperature difference of 20 K and the airflow 1200m3/h
(6) At water temperature 80/60oC, inlet air temperature 5oC and 1200 m3/h of air flow

MAIN DIMENSIONS:

ox

Heating capacities OXeN:

OXeN
Tp1 PT Qw Δpw Tp2 PT Qw Δpw Tp2 PT Qw Δpw Tp2 PT Qw Δpw Tp2 PT Qw Δpw Tp2
[°C] [kW] [l/h] [kPa] [°C] [kW] [l/h] [kPa] [°C] [kW] [l/h] [kPa] [°C] [kW] [l/h] [kPa] [°C] [kW] [l/h] [kPa] [°C]
Tw1/Tw2 = 90/70°C Tw1/Tw2 = 80/60°C Tw1/Tw2 = 70/50°C Tw1/Tw2 = 60/40°C Tw1/Tw2 = 50/30°C
-5 13,3 587 12,1 28 11,6 507 9,6 24 9,8 429 7,3 19 8,0 350 5,3 15 6,2 270 3,5 10
0 12,5 552 10,9 31 10,8 473 8,5 27 9,0 394 6,3 22 7,2 315 4,4 18 5,4 235 2,7 13
5 11,7 518 9,7 34 10 438 7,4 30 8,2 359 5,3 25 6,4 280 3,6 21 4,6 199 2,0 16
10 10,9 483 8,5 37 9,2 404 6,4 33 7,4 324 4,4 28 5,6 244 2,8 24 3,7 161 1,4 19
15 10,2 449 7,5 40 8,4 369 5,4 35 6,6 289 3,6 31 4,8 208 2,1 27 2,8 122 0,9 22
20 9,4 414 6,5 43 7,6 334 4,5 38 5,8 253 2,9 34 3,9 171 1,5 30 1,3 56 0,2 23

V – air flow
PT – heating capacity
Tp1 – inlet air temperature
Tp2 – outlet air temperature
Tw1 – inlet water temperature
Tw2 – outlet water temperature
Qw – water stream flow in the heat exchanger
Δpw – water pressure drop in heat exchanger