ELiS DUO is a curtain-heater unit, which combines two functions. It is 2-in-1 unit, which provides air barrier in the door opening while heating the room simultaneously.
The main task is to protect door opening. Additionally, the auxiliary air stream enables heating of the room.
High efficiency of heat exchange is possible due to a large surface of aluminium fins mounted on copper tubes.
Adjustable air blades make it possible to direct the warm air stream into the room. Regulated angle of the air barrier outlet make possible to adjust the airflow to the door opening.
Fans made of light and durable plastic ensure silent operation and lower weight of the unit.
Advanced control system enables the connection of the unit to BMS an intelligent building management system.
Two versions of the unit are available: with water heat exchanger and with electric heaters.
Modern design of the unit makes it especially suitable for buildings with high aesthetic values.
Wherever there is a need of heating the room while providing air barrier in the door opening, e.g. small grocery stores, gas stations etc.
Basic operation of the air curtains is ensured by built-in connection terminal. Advanced external DRV control system enables communication with BMS and selection of operation mode.
Functionality – 2-in-1 unit. Ensures air barrier in the door opening while heating the room simultaneously.
Design - modern design of the unit was developed in cooperation with an experienced team of industrial designers.
Construction - the use of aluminium for the construction of the body of the unit and the fans made of plastic allowed for a significant reduction of weight and noise level of the unit. Adjustable air outlets make it possible to set the suitable angle of both air streams.
ELiS DUO is a curtain-heater unit, which combines two functions. It is 2-in-1 unit, which provides air barrier in the door opening while heating the room simultaneously.
The main task is to protect door opening. Additionally, the auxiliary air stream enables heating of the room.
High efficiency of heat exchange is possible due to a large surface of aluminium fins mounted on copper tubes.
Adjustable air blades make it possible to direct the warm air stream into the room. Regulated angle of the air barrier outlet make possible to adjust the airflow to the door opening.
Fans made of light and durable plastic ensure silent operation and lower weight of the unit.
Advanced control system enables the connection of the unit to BMS an intelligent building management system.
Two versions of the unit are available: with water heat exchanger and with electric heaters.
Modern design of the unit makes it especially suitable for buildings with high aesthetic values.
Wherever there is a need of heating the room while providing air barrier in the door opening, e.g. small grocery stores, gas stations etc.
Basic operation of the air curtains is ensured by built-in connection terminal. Advanced external DRV control system enables communication with BMS and selection of operation mode.
Functionality – 2-in-1 unit. Ensures air barrier in the door opening while heating the room simultaneously.
Design - modern design of the unit was developed in cooperation with an experienced team of industrial designers.
Construction - the use of aluminium for the construction of the body of the unit and the fans made of plastic allowed for a significant reduction of weight and noise level of the unit. Adjustable air outlets make it possible to set the suitable angle of both air streams.
DUO-W-100 | DUO-W-200 | DUO-E-100 | |
Power supply [V/Hz] | 230 / 50 | 230 / 50 | 3 x 400 / 50 |
Power consumption [kW] | 0,25 | 0,43 | 10,1 |
Current consumption [A] | 1,1 | 1,85 | 14,7 |
IP | 21 | 21 | 21 |
Insulation class | F | F | F |
Hydraulic connection ["] | ½” | ½” | ½” |
Acoustic pressure level [dB(A)]* | 56 | 59 | 56 |
Air temperature rise [oC] | 30 | 23 | 20 |
Max. operating pressure [MPa] | 1,6 | 1,6 | 1,6 |
Weight of unit [kg] | 23,9 | 41,1 | 28,5 |
Weight of unit filled with water [kg] | 25,3 | 42,8 | - |
* Acoustic pressure level at a distance of 2 m from the unit, in the room of medium capabillity of sound absorption and 500 m3 of cubic measure.
** DUO-W at inlet air 10°C and heating medium temperature 90/70°C. DUO-E at inlet air 10°C.
Air curtain | |||||||||
Tp1 | V | PT | Qw | Δpw | Tp2 | PT | Qw | Δpw | Tp2 |
°C | m3/h | kW | l/h | kPa | °C | kW | l/h | kPa | °C |
Tw1 / Tw2 = 90/70oC | Tw1 / Tw2 = 80/60oC | ||||||||
0 | 800/1100/1400 | 11,6/14,3/16,5 | max.1095 | max.11,9 | 43/38/35 | 9,9/12,2/14,2 | max.936 | max.9,2 | 37/33/30 |
5 | 10,9/13,3/15,5 | 45/41/38 | 9,2/11,3/13,1 | 39/36/33 | |||||
10 | 10,1/12,5/14,5 | 47/43/40 | 8,5/10,4/12,0 | 41/38/35 | |||||
15 | 9,4/11,5/13,4 | 49/46/43 | 7,7/9,5/11,0 | 43/40/38 | |||||
20 | 8,7/10,7/12,3 | 52/48/46 | 7,0/8,6/9,9 | 46/43/41 | |||||
Tw1 / Tw2 = 70/50oC | Tw1 / Tw2 = 70/40oC | ||||||||
0 | 800/1100/1400 | 8,3/10,2/11,9 | Max. 778 | max.6,7 | 31/27/25 | 6,9/8,5/9,8 | max.429 | max.2,3 | 26/23/21 |
5 | 7,6/9,3/10,8 | 33/30/28 | 6,1/7,6/8,7 | 28/25/24 | |||||
10 | 6,8/8,4/9,7 | 35/32/30 | 5,3/6,5/7,6 | 30/28/26 | |||||
15 | 6,0/7,5/8,7 | 37/35/33 | 4,5/5,5/6,5 | 31/30/29 | |||||
20 | 5,3/6,5/7,5 | 39/37/36 | 3,6/4,5/5,3 | 33/32/31 | |||||
Tw1 / Tw2 = 60/40oC | Tw1 / Tw2 = 50/40oC | ||||||||
0 | 800/1100/1400 | 6,7/8,1/9,5 | max.620 | max.4,6 | 25/22/20 | 6,4/7,9/9,1 | max.1194 | max.15,4 | 24/21/19 |
5 | 5,7/7,3/8,4 | 27/24/23 | 5,7/6,9/8,0 | 26/24/22 | |||||
10 | 5,1/6,3/7,3 | 29/27/25 | 4,9/6,0/7,0 | 28/26/25 | |||||
15 | 4,3/5,3/6,2 | 31/29/28 | 4,1/5,0/5,9 | 30/29/27 | |||||
20 | 3,5/4,3/5,0 | 33/32/31 | 3,4/4,1/4,8 | 32/31/30 |
Fan heater | |||||||||
Tp1 | V | PT | Qw | Δpw | Tp2 | PT | Qw | Δpw | Tp2 |
°C | m3/h | kW | l/h | kPa | °C | kW | l/h | kPa | °C |
Tw1 / Tw2 = 90/70oC | Tw1 / Tw2 = 80/60oC | ||||||||
0 | 400/550/700 | 5,8/7,2/8,3 | max.1095 | max.11,9 | 43/38/35 | 5,0/6,1/7,1 | max.936 | max.9,2 | 37/33/30 |
5 | 5,5/6,7/7,8 | 45/41/38 | 4,6/5,7/6,6 | 39/36/33 | |||||
10 | 5,1/6,3/7,3 | 47/43/40 | 4,3/5,2/6,0 | 41/38/35 | |||||
15 | 4,7/5,8/6,7 | 49/46/43 | 3,9/4,8/5,5 | 43/40/38 | |||||
20 | 4,4/5,4/6,2 | 52/48/46 | 3,5/4,3/5,0 | 46/43/41 | |||||
Tw1 / Tw2 = 70/50oC | Tw1 / Tw2 = 70/40oC | ||||||||
0 | 400/550/700 | 4,2/5,1/6,0 | max.778 | max.6,7 | 31/27/25 | 3,5/4,3/4,9 | max.429 | max.2,3 | 26/23/21 |
5 | 3,8/4,7/5,4 | 33/30/28 | 3,1/3,8/4,4 | 28/25/24 | |||||
10 | 3,4/4,2/4,9 | 35/32/30 | 2,7/3,3/3,8 | 30/28/26 | |||||
15 | 3,0/3,8/4,4 | 37/35/33 | 2,3/2,8/3,3 | 31/30/29 | |||||
20 | 2,7/3,3/3,8 | 39/37/36 | 1,8/2,3/2,7 | 33/32/31 | |||||
Tw1 / Tw2 = 60/40oC | Tw1 / Tw2 = 50/40oC | ||||||||
0 | 400/550/700 | 3,4/4,1/4,8 | max.620 | max.4,6 | 25/22/20 | 3,2/4,0/4,6 | max.1194 | max.15,4 | 24/21/19 |
5 | 2,9/3,7/4,2 | 27/24/23 | 2,9/3,5/4,0 | 26/24/22 | |||||
10 | 2,6/3,2/3,7 | 29/27/25 | 2,5/3,0/3,5 | 28/26/25 | |||||
15 | 2,2/2,7/3,1 | 31/29/28 | 2,1//2,5/3,0 | 30/29/27 | |||||
20 | 1,8/2,2/2,5 | 33/32/31 | 1,7/2,1/2,4 | 32/31/30 |
Air curtain | |||||||||||
Tp1 | V | PT | Qw | Δpw | Tp2 | PT | Qw | Δpw | Tp2 | ||
°C | m3/h | kW | l/h | kPa | °C | kW | l/h | kPa | °C | ||
Tw1 / Tw2 = 90/70oC | Tw1 / Tw2 = 80/60oC | ||||||||||
0 | 1700/2250/3000 | 19/23/26,6 | max.1465 | max.18,9 | 34/30/27 | 16,3/19,4/22,8 | max.1252 | max.14,5 | 29/26/23 | ||
5 | 17,8/21,1/24,9 | 36/33/30 | 15,1/17,9/21,1 | 32/29/26 | |||||||
10 | 16,6/19,7/23,2 | 39/36/33 | 13,8/16,5/19,7 | 34/32/29 | |||||||
15 | 15,4/18,2/21,5 | 42/39/36 | 12,6/15/17,7 | 37/35/33 | |||||||
20 | 14,2/16,8/19,8 | 45/42/40 | 11,2/13,6/16 | 40/38/36 | |||||||
Tw1 / Tw2 = 70/50oC | Tw1 / Tw2 = 70/40oC | ||||||||||
0 | 1700/2250/3000 | 13,6/16,2/19 | max.1039 | max.10,6 | 24/21/19 | 11,2/13,4/15,7 | max.571 | max.3,6 | 20/18/16 | ||
5 | 12,3/14,6/17,3 | 27/24/22 | 10/11,9/14 | 23//21/19 | |||||||
10 | 11,1/13,2/15,6 | 30/27/26 | 8,7/10,4/12,2 | 25/24/22 | |||||||
15 | 9,8/11,8/13,8 | 32/30/29 | 7,4/8,8/10,4 | 28/26/25 | |||||||
20 | 8,6/10,3/12,1 | 35/33/32 | 6,0/7,2/8,5 | 30/29/28 | |||||||
Tw1 / Tw2 = 60/40oC | Tw1 / Tw2 = 50/40oC | ||||||||||
0 | 800/1100/1400 | 10,8/12,9/15,1 | max.826 | max.7,2 | 19/17/15 | 10,5/12,5/14,7 | max.1599 | max.24,4 | 19/17/15 | ||
5 | 9,6/11,4/13,4 | 22/20/19 | 9,2/11/13 | 21/20/18 | |||||||
10 | 8,4/9,9/11,7 | 25/23/22 | 8,0/9,5/11,2 | 24/23/21 | |||||||
15 | 7,1/8,4/9,9 | 27/26/25 | 6,8/8,1/9,5 | 27/26/24 | |||||||
20 | 5,8/6,9/8,2 | 30/29/28 | 5,5/6,6/7,7 | 30/29/28 | |||||||
Fan heater | |||||||||||
Tp1 | V | PT | Qw | Δpw | Tp2 | PT | Qw | Δpw | Tp2 | ||
°C | m3/h | kW | l/h | kPa | °C | kW | l/h | kPa | °C | ||
Tw1 / Tw2 = 90/70oC | Tw1 / Tw2 = 80/60oC | ||||||||||
0 | 400/550/700 | 4,7/5,8/6,6 | max.1465 | max.18,9 | 34/30/27 | 4,1/4,8/5,7 | max.1252 | max.14,5 | 29/26/23 | ||
5 | 4,4/5,3/6,2 | 36/33/30 | 3,8/4,5/5,3 | 32/29/26 | |||||||
10 | 4,1/4,9/5,8 | 39/36/33 | 3,5/4,1/4,9 | 34/32/29 | |||||||
15 | 3,8/4,6/5,4 | 42/39/36 | 3,2/3,8/4,4 | 37/35/33 | |||||||
20 | 3,5/4,2/5,0 | 45/42/40 | 2,8/3,4/4,0 | 40/38/36 | |||||||
Tw1 / Tw2 = 70/50oC | Tw1 / Tw2 = 70/40oC | ||||||||||
0 | 400/550/700 | 3,4/4/4,7 | max.1039 | max.10,6 | 24/21/19 | 2,8/3,3/3,9 | max.571 | max.3,6 | 20/18/16 | ||
5 | 3,1/3,7/4,3 | 27/24/22 | 2,5/3/3,5 | 23//21/19 | |||||||
10 | 2,8/3,3/3,9 | 30/27/26 | 2,2/2,6/3 | 25/24/22 | |||||||
15 | 2,5/2,9/3,5 | 32/30/29 | 1,8/2,2/2,6 | 28/26/25 | |||||||
20 | 2,2/2,6/3,0 | 35/33/32 | 1,5/1,8/2,1 | 30/29/28 | |||||||
Tw1 / Tw2 = 60/40oC | Tw1 / Tw2 = 50/40oC | ||||||||||
0 | 400/550/700 | 2,7/3,2/3,8 | max.826 | max.7,2 | 19/17/15 | 2,6/3,1/3,7 | max.1599 | max.24,4 | 19/17/15 | ||
5 | 2,4/2,9/3,4 | 22/20/19 | 2,3/2,8/3,2 | 21/20/18 | |||||||
10 | 2,1/2,5/2,9 | 25/23/22 | 2/2,4/2,8 | 24/23/21 | |||||||
15 | 1,8/2,1/2,5 | 27/26/25 | 1,7/2/2,4 | 27/26/24 | |||||||
20 | 1,4/1,7/2 | 30/29/28 | 1,4/1,6/1,9 | 30/29/28 |
V – air flow
PT – heating capacity
Tp1 – inlet air temperature
Tp2 – outlet air temperature
Tw1 – inlet water temperature
Tw2 – outlet water temperature
Δpw – water pressure drop in heat exchanger
Qw – water stream flow in the heat exchanger
For operating parameters concerning other heating medium temperatures, please contact Sales Office.
The ELiS DUO curtain-heater can be installed using installation console or pins. Installation console enables the installation of the unit in two configurations.
Installation tips:
For efficient operation of the unit the air barrier has to be ensured in entire door opening space. In order to protect the wider door openings, the ELiS DUO curtain-heaters can be combined together.
Incorrect installation may result in heat loss during the winter and chill loss in the air-conditioned rooms during the summer.
(5.12 MB)
(3.39 MB)
(130.85 kB)
(20.14 MB)
(983.75 kB)
(16.24 MB)
(801.93 kB)
Localization: Pomeranian, Poland
Localization: Łódź, Poland
Localization: West Pomeranian, Poland
Localization: Masovian, Poland
Localization: Silesian, Poland
Localization: Greater Poland, Poland
Localization: Silesian, Poland
Localization: Silesian, Poland
DUO-W-100 | DUO-W-200 | DUO-E-100 | |
Fonte de alimentação [V / Hz] | 230 / 50 | 230 / 50 | 3 x 400 / 50 |
Consumo de energia [kW] | 0,25 | 0,43 | 10,1 |
Consumo atual [A] | 1,1 | 1,85 | 14,7 |
IP | 21 | 21 | 21 |
Classe de isolamento | F | F | F |
Conexão hidráulica ["] | ½” | ½” | ½” |
Nível de pressão acústica [dB (A)] * | 56 | 59 | 56 |
Aumento da temperatura do ar [ o C] | 30 | 23 | 20 |
Max. pressão de operação [MPa] | 1,6 | 1,6 | 1,6 |
Peso da unidade [kg] | 23,9 | 41,1 | 28,5 |
Peso da unidade cheio com água [kg] | 25,3 | 42,8 | - |
* Acoustic pressure level at a distance of 2 m from the unit, in the room of medium capabillity of sound absorption and 500 m3 of cubic measure.
** DUO-W at inlet air 10°C and heating medium temperature 90/70°C. DUO-E at inlet air 10°C.
ELiS DUO cortina-aquecedor pode ser instalada usando instalação consola e pins. Consola permite a instalação das unidades em duas configurações.
Dicas de instalação:
Para o funcionamento eficiente da unidade, a barreira de ar deve ser assegurada em todo o espaço de abertura da porta. Para proteger as aberturas mais largas da porta, os cortinas de aquecimento ELiS DUO podem ser combinadas.
A instalação incorreta pode resultar em perda de calor durante o inverno e perda de frio nos quartos climatizados durante o verão.